Description
Performance that advances your lab
- Improve laboratory productivity by transitioning methods to UPLC Technology
- Improve the characterization of your most complex samples through enhanced resolution
- Leverage advanced tools that simplify and streamline your method development workflow
- Improve precision with state-of-the-art high pressure binary or quaternary solvent blending
- Increase the analytical value of your samples by leveraging optical and mass information
- Match the need of your laboratory through support of your existing HPLC, UHPLC, and UPLC methods
The UPLC difference
The ACQUITY UPLC H-Class PLUS System is the next evolution of UltraPerformance instrumentation, providing the high resolution of a quaternary or binary LC System.
Achieving true UPLC performance requires that system dispersion (or extra-column band spread) to be matched to the peak widths associated with narrowbore columns packed with sub-2-μm particles. While other systems might be designed for high pressure, it doesn’t mean they’re designed to deliver the sharp peaks associated with UPLC performance and the ACQUITY UPLC H-Class PLUS System.
Comparison of the same method with the same column on a low-dispersion ACQUITY UPLC H-Class PLUS System versus a higher-dispersion UHPLC system.
Take your methods to the next performance levelLeverage the benefits of UPLC Technology to improve your existing HPLC methods. By scaling your methods to UPLC, your laboratory will benefit from the combination of increased resolution, sensitivity, and speed that comes with modern small particle chemistries. With novel method conversion tools such as the Columns Calculator and the Column Coach, the process of upgrading your methods has never been easier. |
zoom
|
zoom
|
Support both HPLC and UPLC methodsNeed an LC platform that can run your HPLC methods today before you begin the transition to UPLC? The ACQUITY UPLC H-Class PLUS System was designed to support both HPLC and UPLC methods so that you can invest in your laboratory’s future but still support your existing methods until you’re ready to deploy UPLC. |
Discovering the best method gets you the best results
Get the versatility to discover the best set of chromatographic conditions for your sample, providing a more robust method. The flexibility of the ACQUITY UPLC H-Class PLUS Quaternary System allows you to automatically screen important method parameters, including:
- Up to six columns in independently temperature controlled compartments
- pH and ionic strength with Auto•Blend Plus Technology
- Optional and integrated solvent selection valve expands access to six additional mobile phase lines
- 11 unique gradient profiles
Changes in peak elution order, due to different pH conditions programmed with Auto-Blend Plus, were easily tracked with the ACQUITY QDa detector for this example of metoclopramide and its related compounds.
Combining these system capabilities with the Empower Sample Set Generator can help you to completely automate your method development experiment And with the ACQUITY QDa Detector , method development can be significantly accelerated by utilizing mass information to track the movement of peaks when evaluating different method conditions.
zoom
|
Deliver greater speed and precision for routine analysesThe ACQUITY UPLC H-Class PLUS Binary System combines the proven reliability and performance of the ACQUITY UPLC H-Class PLUS System with the precision and lowest system volume offered by our high-pressure mixing binary solvent manager, allowing you to:
Combine the capabilities of the ACQUITY UPLC H-Class PLUS Binary System with Waters tandem quadruple technology for routine quantitative UPLC-MS/MS applications, so you can confidently quantify and trace components in the most complex of samples. |
Features and Benefits
- Get the flexibility of multi-solvent blending with the Quaternary Solvent Manager (QSM), and blend four solvents in any combination or proportion. Expand to up to nine solvents with the optional and integrated solvent-select valve for even greater flexibility. Automated solvent compressibility allows you to run any solvent in any combination without loss in accuracy or precision.
- Deliver precise and accurate binary solvent blending with the Binary Solvent Manager (BSM) at pressures up to 15,000 psi. Two integrated solvent select valves provide access to a total of four solvents. Automated solvent compressibility, integrated solvent degassing, and programmable seal wash maximize flow accuracy, precision, and reliability.
- High-precision injections with direct inject sampling. The needle-in-flow path design ensures an accurate needle seal at high pressure. Injection volumes from 0.1 μL up to 1 mL are supported. Ultra-low carryover is managed through programmable method settings to ensure compatibility even with the most sensitive mass spectrometers.
- Accurate temperature control across the entire column. Configurable for 1 to 6 columns, each housed in individual temperature controlled zones with active pre-heating and a temperature range of 4 to 90 °C.
- Low-dispersion detection capabilities. The ACQUITY UPLC H-Class PLUS System is the only LC system in the market with a wide range of detectors that have been optimized for true UPLC performance. Minimizing dispersion and optimizing the electronics and optical paths for the narrow UPLC peaks yields the highest sensitivity and repeatability with the most accurate quantification.
- Significantly reduce the time you spend in the prep lab by automating the formulation of mobile phases at specific pH and ionic strength from reservoirs of pure solvents or concentrated stock solutions using Auto•Blend Plus Technology, available with the ACQUITY UPLC H-Class PLUS Quaternary System. Compatible with reversed phase, IEX, and SEC, this technology makes routine analyses easier to manage and execute and streamlines method development and method robustness testing by allowing you to test even the smallest changes in pH and ionic strength without needing to make each individual buffer.
- Automatically manage gradient start time and pre-injection steps in parallel with SmartStart Technology. This allows you to compensate for system volume differences when transferring methods between different LC systems or to minimize inject-to-inject cycle times for high throughput applications.
- Gradient SmartStart Easily adjusts for system volume differences when transferring methods from an alternative LC system without alteration to the method table.
- Supported in Empower, Masslynx, UNIFI, and several 3rd party software packages.
Description | Year |
---|---|
ACQUITY UPLC H-Class PLUS System with Binary Solvent Management Instrument Specifications Format: PDF | File Size: 114.97 kB | Content Subtype: Specifications |
2019 |
ACQUITY UPLC H-Class PLUS System Specifications Format: PDF | File Size: 102.42 kB | Content Subtype: Specifications |
2018 |
ACQUITY UPLC H-Class PLUS System with 2D Technology Specifications Format: PDF | File Size: 104.64 kB | Content Subtype: Specifications |
2018 |
ACQUITY UPLC H-Class System specifications Format: PDF | File Size: 349.68 kB | Content Subtype: Specifications |
2015 |
ACQUITY UPLC H-Class and ACQUITY UPLC H-Class Bio System Accessories Format: PDF | File Size: 2215.44 kB | Content Subtype: Brochures |
2013 |
The Impact of Spare Parts Design and Manufacturing on ACQUITY UPLC System Performance Format: PDF | File Size: 1885.91 kB | Content Subtype: White Papers |
2011 |
Manufacturer Reduces Vitamin QC Analysis Times by Up to 90% Format: PDF | File Size: 462.52 kB | Content Subtype: Case Studies |
2020 |
Medicinal Chemistry Brochure – Waters Holistic Medicinal Chemistry Solutions Format: PDF | File Size: 547.51 kB | Content Subtype: Brochures |
2020 |
Combining Thin-Layer Chromatography (TLC) and UltraPerformance Liquid Chromatography (UPLC) with Mass Detection in a Synthetic Chemistry Environment Format: PDF | File Size: 891.18 kB | Content Subtype: Brochures |
2019 |
A Complete Solution to Perform a Systematic Screening Protocol for LC Method Development Format: PDF | File Size: 2109.35 kB | Content Subtype: White Papers |
2018 |
ACQUITY UPLC H-Class PLUS System Brochure Format: PDF | File Size: 1115.58 kB | Content Subtype: Brochures |
2018 |
Building Laboratory Capacity to Ensure Cannabis Safety, Quality, and Efficacy Format: PDF | File Size: 1954.63 kB | Content Subtype: Case Studies |
2018 |
Column Performance and Data Management Using eCord Intelligent Chip Technology, ACQUITY UPLC System, and Empower 3 Software Format: PDF | File Size: 1282.36 kB | Content Subtype: White Papers |
2018 |
Dwell Volume and Extra-Column Volume: What Are They and How Do They Impact Method Transfer Format: PDF | File Size: 1007.76 kB | Content Subtype: White Papers |
2018 |
LC Portfolio Brochure Format: PDF | File Size: 2574.97 kB | Content Subtype: Brochures |
2018 |
Chromatography Data System Solutions for the Food Industry Format: PDF | File Size: 7179.11 kB | Content Subtype: Brochures |
2017 |
Ensuring Food Ingredient Quality and Consistency with a Novel Mass Detection Technology Format: PDF | File Size: 565.79 kB | Content Subtype: Case Studies |
2017 |
Traditional Chinese Medicine Granule Solution Format: PDF | File Size: 7980.03 kB | Content Subtype: Brochures |
2017 |
Seamless Integration of Mass Detection into the UV Chromatographic Workflow Format: PDF | File Size: 1631.67 kB | Content Subtype: White Papers |
2016 |
Tobacco Analysis Solutions for Regulatory Compliance and Research Format: PDF | File Size: 3214.25 kB | Content Subtype: Brochures |
2016 |
Advancing the Characterization and Quality Control of Botanical Extracts with Mass Spectrometry Format: PDF | File Size: 1080.23 kB | Content Subtype: Case Studies |
2015 |
Agrochemical Solutions Format: PDF | File Size: 4941.02 kB | Content Subtype: Brochures |
2015 |
Future-Proof Solutions for Regulated Laboratories in the Face of Changing USP <621> Guidelines Format: PDF | File Size: 587.33 kB | Content Subtype: White Papers |
2015 |
eBook: The Missing Link between HPLC and UPLC Format: PDF | File Size: 1256.38 kB | Content Subtype: Case Studies |
2015 |
ACQUITY UPLC H-Class Does Work of 2 HPLC Systems: Reduces a Full Day’s Work to just 2.5 Hours in Pharma QC Format: PDF | File Size: 1057.62 kB | Content Subtype: Case Studies |
2014 |
Description | Year |
---|---|
Waters Product Guide Format: PDF | File Size: 10203.4 kB – |
2018 |
Description | Year |
---|---|
Right System, Right Time Format: PDF | File Size: 219.66 kB | Content Subtype: Article Reprints |
2010 |
The Missing Link Between HPLC and UPLC Technology Format: PDF | File Size: 1452.33 kB | Content Subtype: Article Reprints |
2010 |
Waters Features Newest UPLC System Globally Format: PDF | File Size: 158.79 kB | Content Subtype: Article Reprints |
2010 |
NGP Europe: Facilitating Continuous Improvement Format: PDF | File Size: 224.42 kB | Content Subtype: Article Reprints |
2010 |